RSIS Repository Open-access research from RSIS International journals

International Journal of Research and Innovation in Social Science (IJRISS)

Effect of Cooling Variation in Core and Cavity Temperatures on Volumetric Shrinkage in the Plastic Injection Moulding Process

byWan Noor Azrina Wan Azhari; Mohd Amran Md Ali; Ahmad Shahir Jamaludin

Published December 11, 2025  •  Vol. 9, Issue 11, pp. 4910–4918Open Access
DOI: 10.47772/IJRISS.2025.91100387

Abstract

Plastic injection moulding (PIM) is a widely used manufacturing process for producing high-precision plastic components. Among various process parameters thermal condition particularly core and cavity temperatures and their respective cooling rates significantly affect the volumetric shrinkage of moulded parts. Non-uniform cooling due to imbalanced temperature profiles can lead to percentage volumetric shrinkage, causing residual stresses, dimensional inaccuracies, and warpage. This study investigates the effects of core temperature, cavity temperature, and cooling time on volumetric shrinkage in the injection moulding process. A statistical approach using Design of Experiments (DOE) based on the Response Surface Methodology (RSM) was employed to analyze the relationships and interactions among these parameters. The results indicate that core temperature has the most significant parameter influence on volumetric shrinkage, followed by cavity temperature. However, cooling time alone showed minimal statistical impact. However, a notable interaction between core temperature and cooling time was observed, suggesting a synergistic effect on volumetric shrinkage behavior. Optimization of process parameters yielded optimal settings of 15 °C core temperature, 60.45 °C cavity temperature, and 12.5 s cooling time. These conditions reduced percentage volumetric shrinkage to 36.59%, significantly improving part dimensional stability. The predictive model demonstrated high accuracy, with an average differential of only 1.43% compared to experimental results. These findings highlight the critical role of thermal management and parameter interactions in minimizing volumetric shrinkage in plastic injection moulding.

Keywords: Plastic injection moulding, volumetric shrinkage, core temperature, cavity temperature

JournalInternational Journal of Research and Innovation in Social Science (IJRISS)
ISSN2454-6186
Volume / IssueVolume 9, Issue 11
Pages4910–4918
Publication dateDecember 11, 2025
DOI10.47772/IJRISS.2025.91100387
PublisherRSIS International
LicenseOpen Access

How to cite this article

Wan Noor Azrina Wan Azhari, Mohd Amran Md Ali, & Ahmad Shahir Jamaludin (2025). Effect of Cooling Variation in Core and Cavity Temperatures on Volumetric Shrinkage in the Plastic Injection Moulding Process. International Journal of Research and Innovation in Social Science (IJRISS), 9(11), 4910-4918. https://doi.org/10.47772/IJRISS.2025.91100387

BibTeX

@article{Wan2025,
  title   = {Effect of Cooling Variation in Core and Cavity Temperatures on Volumetric Shrinkage in the Plastic Injection Moulding Process},
  author  = {Wan Noor Azrina Wan Azhari and Mohd Amran Md Ali and Ahmad Shahir Jamaludin},
  journal = {International Journal of Research and Innovation in Social Science (IJRISS)},
  volume  = {9},
  number  = {11},
  pages   = {4910--4918},
  year    = {2025},
  doi     = {10.47772/IJRISS.2025.91100387},
  publisher = {RSIS International}
}